{"product_id":"majestic-slp-4x-6-5-8-high-pitch-roof-flashing-7-12-12-12-slp-rf12","title":"Majestic SLP 4 Inch x 6-5\/8 Inch High Pitch Roof Flashing 7\/12-12\/12 - SLP-RF12","description":"\u003cp\u003eThe Majestic SLP-RF12 is the roof flashing for a 7\/12 to 12\/12 pitch roof on a Majestic SLP direct vent run (pitch range per current listing). It weatherproofs the point where the vent passes through the roof and works with a storm collar and the vertical termination cap.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFor 7\/12 to 12\/12 roof pitch\u003c\/li\u003e\n\u003cli\u003eSeals the roof penetration under the shingles\u003c\/li\u003e\n\u003cli\u003eUse with a storm collar and vertical termination cap\u003c\/li\u003e\n\u003cli\u003eGenuine Majestic part\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Specifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSLP-RF12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eRoof flashing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof pitch\u003c\/td\u003e\n\u003ctd\u003e7\/12 to 12\/12 (per listing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVent system\u003c\/td\u003e\n\u003ctd\u003eMajestic SLP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompanion part\u003c\/td\u003e\n\u003ctd\u003eVertical cap SLP-TVHW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits\u003c\/td\u003e\n\u003ctd\u003eMajestic Quartz 32\/36\/42, Quartz Platinum 36, Jade 32\/42 and Meridian 36\/42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662492923839\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eWhat Is Included and What You Will Need\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIncluded: (1) Majestic SLP-RF12\u003c\/li\u003e\n\u003cli\u003eRequired: storm collar, vertical termination cap and the firestops shown in your manual\u003c\/li\u003e\n\u003cli\u003eRequired: a fireplace whose manual lists SLP venting, such as the \u003ca href=\"https:\/\/nycfireplaceshop.com\/products\/majestic-quartz-direct-vent-gas-fireplace-32\"\u003eQuartz 32\u003c\/a\u003e, \u003ca href=\"https:\/\/nycfireplaceshop.com\/products\/majestic-quartz-42-direct-vent-gas-fireplace-quartz42\"\u003eQuartz 42\u003c\/a\u003e, \u003ca href=\"https:\/\/nycfireplaceshop.com\/products\/majestic-jade-32-direct-vent-gas-fireplace-jade32in-b\"\u003eJade 32\u003c\/a\u003e, \u003ca href=\"https:\/\/nycfireplaceshop.com\/products\/majestic-jade-42-direct-vent-gas-fireplace-jade42in-b\"\u003eJade 42\u003c\/a\u003e, \u003ca href=\"https:\/\/nycfireplaceshop.com\/products\/majestic-meridian-36-direct-vent-gas-fireplace\"\u003eMeridian 36\u003c\/a\u003e and \u003ca href=\"https:\/\/nycfireplaceshop.com\/products\/majestic-meridian-direct-vent-gas-fireplace-42\"\u003eMeridian 42\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cp\u003eMeasure the roof pitch before ordering; the flashing range is fixed. Have a qualified technician install it per the kit instructions and fireplace manual. In NYC, gas appliance and vent work is done by a licensed master plumber under the NYC Fuel Gas Code.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.nycfireplaces.com\/consultation-design\/\"\u003eBook a design consultation\u003c\/a\u003e to plan the vent run.\u003c\/p\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0489\/1541\/5207\/files\/Quartz32-36-42_Installation-Manual.pdf?v=1787151570\" target=\"_blank\" rel=\"noopener\"\u003eMajestic Quartz 32\/36\/42 Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0489\/1541\/5207\/files\/2595_980_MER36-MER42_INSTALL.pdf?v=1787151571\" target=\"_blank\" rel=\"noopener\"\u003eMajestic Meridian MER36\/MER42 Installation Manual (2595-980)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003ch4\u003eWhich flashing do I need?\u003c\/h4\u003e\u003cp\u003eMatch it to your roof: RF6 covers 0\/12 to 6\/12 and RF12 covers 7\/12 to 12\/12 on DVP runs. Steeper roofs need a custom solution.\u003c\/p\u003e\u003ch4\u003eDoes flashing come with the cap?\u003c\/h4\u003e\u003cp\u003eNo. The flashing, storm collar and termination cap are ordered separately.\u003c\/p\u003e\u003cp\u003eRelated reading: \u003ca href=\"https:\/\/nycfireplaceshop.com\/blogs\/buying-guides\/direct-vent-gas-fireplace-buying-guide\"\u003eDirect vent gas fireplace buying guide\u003c\/a\u003e, \u003ca href=\"https:\/\/nycfireplaceshop.com\/blogs\/news\/nyc-fireplace-code-guide\"\u003eNYC fireplace code guide\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWarranty\u003c\/h3\u003e\u003cp\u003eHearth and Home Technologies limited warranty (table 4021-645 in Majestic owner's manuals): chimney and terminations 7 years parts and 3 years labor from installation; purchased replacement parts 1 year, parts only. Purchase from an authorized HHT dealer is required.\u003c\/p\u003e","brand":"Majestic","offers":[{"title":"Default Title","offer_id":46101170422018,"sku":"SLP-RF12","price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0489\/1541\/5207\/files\/SLP.png?v=1745372740","url":"https:\/\/nycfireplaceshop.com\/products\/majestic-slp-4x-6-5-8-high-pitch-roof-flashing-7-12-12-12-slp-rf12","provider":"NYC Fireplaces \u0026 Outdoor Kitchens","version":"1.0","type":"link"}