Marquis Sentinel Direct Vent Freestanding Gas Stove FDV350
Marquis Sentinel Direct Vent Freestanding Gas Stove FDV350 - Natural Gas / Millivolt is backordered and will ship as soon as it is back in stock.
- See it in person at our Queens showroom, 147+ live displays.
- Factory-authorized Marquis by Kingsman dealer. You keep the full manufacturer warranty.
- Professional installation available across NYC, Long Island, Westchester, northern NJ and Greenwich/Stamford, CT.
Description
Description
Overall Dimensions: 27-5/16 in. W x 19-1/16 in. D x 30-3/8 in. H
The Marquis Sentinel (FDV350) is a traditional freestanding direct vent gas stove with ceramic glass on three sides, so the fire reads from across the room, not just straight on. It is a good fit for a living room, bedroom or den that needs real heat without a chimney.
It runs from 29,000 to 37,000 BTU/h on natural gas and 27,000 to 35,000 BTU/h on propane, uses a dual burner for a fuller flame, and vents through a side wall or straight up through the roof. Choose the control option above: Millivolt (standing pilot, works without power), IPI Proflame 1 (intermittent pilot, upgradeable) or IPI Proflame 2 (full-function remote with flame, fan and thermostat control, factory installed).
Key Specifications
| Model | FDV350N, NE, NE2 (natural gas); FDV350LP, LPE, LPE2 (propane) |
|---|---|
| Input | NG 29,000 to 37,000 BTU/h; LP 27,000 to 35,000 BTU/h |
| Efficiency | FE (CSA P.4.1-15) 67.90% NG, 70.10% LP for PF2 models |
| Type | Freestanding direct vent gas stove |
| Glass | Heat radiating ceramic glass, panoramic view from three sides |
| Controls | Millivolt, IPI Proflame 1 or IPI Proflame 2 with remote |
| Venting | 4 in. / 7 in. direct vent, top vent through a side wall or roof |
| Approvals | Mobile home approved; approved for bedroom or bed-sitting room installation |
| Certification | ANSI Z21.88-2017 / CSA 2.33-2017, CSA 2.17-2017 |
Dimensions and Cutout
| Width | 27-5/16 in. |
|---|---|
| Depth | 19-1/16 in. |
| Height | 30-3/8 in. |
| Flue | 4 in. exhaust, 7 in. outer diameter |
| Clearances | 12 in. sides, 3 in. back, 3 in. sides in a 45 degree corner, 36 in. front |
| Alcove | 30 in. deep maximum, 55-1/2 in. high and 52-1/2 in. wide minimum |
Features
- Ceramic glass on three sides for a panoramic view
- Dual burner system with a realistic flame pattern
- Millivolt and IPI valves run during a power failure with Hi-Low flame adjustment
- Proflame II models include a remote with flame, fan, thermostat and smart thermostat control, with local Wi-Fi compatibility
- Fiber oak log set with embers and black louver
- Can sit directly on carpet, tile or other combustible flooring with no extra floor protection
- Vents through a side wall or straight up through the roof
- Built in Canada by Marquis
What Is Included and What You Will Need
- Included: stove body, burner and controls for the option you select
- Marquis notes components may need to be ordered separately to complete the unit, such as the F35DB black door with ceramic glass shown in the brochure; we confirm the full list with your order
- Optional: F35RL traditional brick liner and F350CSS safety screen barrier
- Optional: heat-activated fan kit with variable speed control
- Required: vent kit, such as the ZDVFK5, ZDVFK8 or ZDVFK20 flex kit
- Optional: F35BVC B-vent converter to convert the stove to 4 in. B-vent
- Required: gas line with shutoff; household power for the optional fan
Installation Notes
The Sentinel uses 4 in. x 7 in. direct vent pipe: Kingsman 4 in. x 7 in. flex vent kits, or M&G DuraVent DirectVent Pro, Ameri-Vent, BDM Pro Form or Selkirk Direct Temp with the approved adapter. Keep 12 in. to combustibles at the sides, 3 in. at the back and 36 in. in front, and follow the alcove limits if it sits in a recess. A product-approved vent terminal must be used, and the stove must be installed by a qualified gas installer to local codes. In New York City, direct vent gas stoves are installed under the NYC Fuel Gas Code by a licensed plumber with DOB filing where required, and the vent termination location usually decides feasibility. Book a free design consultation and we will help you plan the layout, utilities and installation.
Documentation
- Marquis Sentinel Brochure
- Marquis Sentinel FDV350 Installation and Operating Manual
- Proflame II Manual
- Proflame II Remote Guide
- Proflame II Wi-Fi Dongle Manual
- Marquis Collection Brochure
Frequently Asked Questions
Which control option should I choose?
Millivolt is the simplest and runs without power. IPI Proflame 1 lights the pilot only when needed and can be upgraded. IPI Proflame 2 adds a factory-installed remote with flame, fan and thermostat control.
Will it work in a power outage?
Yes. Marquis states the millivolt and IPI valve systems allow operation during a power failure with Hi-Low flame adjustment.
Can it go on carpet?
Yes. The manual allows installation directly on carpet, tile or other combustible flooring with no additional floor protection.
Can it go in a bedroom?
Yes. The Sentinel is approved for installation in a bedroom or bed-sitting room, subject to local code.
Related reading: Direct Vent Gas Fireplace Buying Guide and Gas Fireplace Cost Installed.
Warranty
Kingsman (Marquis) Basic One Year Warranty: for the first year after installation, any defective component part is replaced, with labor paid on Kingsman's rate schedule through an authorized dealer (accent light bulbs, gasketing and paint excluded). Limited Lifetime Warranty: the heat exchanger, combustion chamber and burner are warranted for as long as the original owner owns the stove; labor, material, freight and handling on lifetime-warranty repairs are not covered. Coverage applies while the unit stays at its original installation site in the continental United States, Alaska, Hawaii or Canada.
Marquis Sentinel Direct Vent Freestanding Gas Stove FDV350 - Natural Gas / Millivolt is backordered and will ship as soon as it is back in stock.