Overall Dimensions: blower 25 in. x 30-13/16 in. x 12-3/4 in.; 10 in. round duct (Viking DEV15001 installation instructions)
The Viking DEV15001 is a 1,500 CFM exterior mounted power ventilator: the blower sits on the roof or an outside wall instead of inside the hood, so the motor noise stays outdoors while the hood in the kitchen does the capturing. It connects to the hood through 10 in. round metal duct and a rough-in plate included in the kit.
Viking built it only for its own large hoods: VBCV, VCWH, VWH, TVWH and VCIH wall and island hoods 42 to 66 in. wide, and VDD downdraft ventilators 30 to 48 in. wide. It is not a universal blower, so confirm the hood model before ordering.
Features
- 1,500 CFM exterior power ventilator
- Roof or exterior wall mounting keeps blower noise outside
- 10 in. round duct connection
- 120V, 4.3 A; circuit rated 6 A minimum
- Permanently lubricated motor
- Rough-in plate included for canopy hood installations
Key Specifications
| Model | DEV15001 |
|---|---|
| Type | Exterior mounted ventilator (remote blower) |
| Airflow | 1,500 CFM |
| Duct | 10 in. round, metal ductwork only |
| Electrical | 120V, 60 Hz, 4.3 A; 6 A minimum circuit |
| Mounting | Roof (minimum 2/12 pitch, curb on flat roofs) or exterior wall |
| Compatible hoods | Viking VBCV, VCWH, VWH, TVWH, VCIH wall and island hoods 42 to 66 in. W; VDD downdraft ventilators 30 to 48 in. W |
Dimensions and Openings (Viking installation instructions)
| Blower | 25 in. x 30-13/16 in. x 12-3/4 in. (English section; the French section lists 22 in. for the first figure) |
|---|---|
| Roof cutout | 21 in. W x 20-1/2 in. H shingle area; 11 in. diameter duct hole |
| Wall cutout | 25 in. W x 29-1/2 in. H siding area; 11 in. diameter duct hole |
What Is Included and What You Will Need
- Included: exterior blower and rough-in plate for wall or island canopy hoods; one 12-3/4 x 6-1/2 in. and two 12-3/4 x 3-1/2 in. cover plates for VDD downdraft installations
- Required: a compatible Viking hood or VDD downdraft ventilator, sold separately
- Required: 10 in. round metal duct and elbows, roof or wall flashing, and a 120V circuit run by a licensed electrician
Installation Notes
Mount the blower on the rear slope of the roof or on an outside wall, as close to the hood as possible with the fewest elbows, and run 10 in. round steel duct to the hood. On a flat roof, build a curb that sets the blower at a 2/12 minimum pitch with the discharge facing away from prevailing winds. Wiring must be done by a qualified electrician to code, and make-up air may be needed so other fuel-burning appliances do not backdraft. In New York City, roof and exterior wall penetrations on multifamily buildings usually need building approval, so plan this with the building first. Book a design consultation to plan the hood, duct run and blower location.
Documentation
Frequently Asked Questions
Which hoods does it work with?
Viking VBCV, VCWH, VWH, TVWH and VCIH wall and island hoods 42 to 66 in. wide, and VDD downdraft ventilators 30 to 48 in. wide.
What size duct does it need?
10 in. round metal duct.
Can it go on a wall instead of the roof?
Yes. The instructions cover both roof and exterior wall mounting.
Is it for outdoor grill hoods?
No. It is an exterior mounted blower for Viking indoor hoods and downdraft ventilators.
Related reading: Do You Need a Vent Hood Over an Outdoor Grill? and Outdoor Kitchen Planning Guide.
Warranty
Viking limited warranty applies. The DEV15001 installation instructions do not state the warranty term, so confirm coverage on the Viking warranty card supplied with the ventilator and register it with Viking.
Viking | 1500 CFM Stainless Steel Ventilation Blower is backordered and will ship as soon as it is back in stock.